Page 50 - Besto Rettungswesten 2023
P. 50
HOW THEY OPERATE
Inflatable lifejackets have an inflation valve either automatic or manual connected to an airtight bladder. To operate the manual valve
you simply pull the toggle located at the bottom of the jacket downwards with a jerk and the bladder will start to inflate immediately. The
automatic lifejacket will operate and inflate once it has been immersed in the water for three seconds. An automatic lifejacket can also be
operated manually and both types can be inflated orally by the tube. The oral tube can also be used to deflate the lifejacket. N.B! After gas
inflation the lifejacket must be rearmed. Inside the lifejacket you will find instructions as to which rearming kit to use (see also page 53).
Instructions to complete the rearming procedure are included with our rearming kits.
All Besto lifejackets are fitted with a cylinder safe retainer which will prevent the cylinder from unscrewing itself. See also page 52 for
retrofit/aftermarket cylinder retainers.
Reflective Patches
Oral deflation/ Strong nylon cover
inflation tube
Bladder
Optional: A lifejacket
light can be fitted.
NEW
Cylinder safe
Reflective retainer
Patches Gascylinder
Whistle
Inflation Mechanism
Lifting loop
Auto Bobbin
Manual pull cord
Closing Standard mechanisms Clear indicator Auto “bobbins” Hydrostatic mechanism
mechanisms
Stainless steel Buckle United Moulders standard United Moulders Clear United Moulders Cartridges Hammer hydrostatic
Harness Type mechanism MKS Indicator CXI mechanism inflator MA1 “auto”
See www.cmhammar.com
Plastic Buckle Halkey Roberts United Moulders Halkey Roberts
Waistbelt Type mechanism Pro Sensor/Elite auto bobbin